Fire Rated Doors

Fire Rated Door Sizes in India: Standard Single & Double Leaf

Korindia Standard Single Leaf And Double Leaf Steel Fire Rated Doors In A Commercial Building Corridor

Choosing the right fire rated door size is not only about matching a wall opening. The door leaf, frame, clear passage width, wall construction, hardware, and certification must work as one approved system. A small measurement error can lead to site rework, delayed approvals, or a door that no longer matches its tested configuration.

For most Indian projects, KORINDIA’s standard single-leaf fire rated door size is 1000 x 2100 mm (width x height), while its standard double-leaf fire rated door size is 2000 x 2100 mm. These sizes are offered across FD 60, FD 90, and FD 120 configurations, subject to the tested door design, hardware, frame, and installation details.

This guide explains fire rated door sizes in India in practical terms: what each dimension means, how single and double-leaf doors differ, how to measure before ordering, and when a custom fire door size is the better choice.

Fire Rated Door Sizes: The Direct Answer

1000 X 2100 Mm Single Leaf Red Steel Fire Rated Door With Vision Panel And Closer In A Staircase Enclosure

KORINDIA manufactures fire rated doors in 60, 90, and 120-minute ratings, with standard and project-specific sizes available for commercial, industrial, institutional, and infrastructure applications.

ConfigurationKORINDIA standard leaf sizeTypical use
Single leaf1000 x 2100 mmCorridors, staircases, electrical rooms, service rooms
Double leaf, equal2000 x 2100 mm totalExit routes, plant rooms, warehouses, wider access points
Double leaf, unequalCustomer-specificAreas needing a wider active leaf and narrower access leaf
Custom sizeAs per drawing and engineering reviewIndustrial openings, equipment access, special layouts

These dimensions refer to the door leaf size, not necessarily the structural opening. Always confirm the required opening size with the manufacturer before finalising the civil work.

For wider openings, KORINDIA also supplies steel fire rated doors in double-leaf and unequal-leaf formats, designed around the project’s fire rating, traffic requirement, and wall condition.

Structural Opening vs Clear Opening

2000 X 2100 Mm Equal Double Leaf Steel Fire Rated Door With Panic Bars In An Industrial Warehouse Corridor

Many size-related problems happen because four different measurements are treated as the same thing. They are not.

Structural opening

The structural opening is the finished gap left in the wall for the complete door assembly. It includes allowance for the door frame, fixing clearance, shims, sealant, and installation tolerances.

For example, if a wall is constructed with a 1100 x 2200 mm opening, the actual clear passage after the frame is installed will be smaller.

Clear opening

The clear opening is the unobstructed width and height available when the door is fully open. This is the measurement that matters for evacuation, trolley movement, wheelchair access, and equipment passage.

A 1000 mm wide leaf does not provide a full 1000 mm clear width because the leaf, stop, hinges, and frame geometry reduce the usable passage.

Leaf size

The leaf size is the size of the movable door panel. KORINDIA’s standard single-leaf size of 1000 x 2100 mm means the leaf is 1000 mm wide and 2100 mm high.

Frame size

The frame size is the outer dimension of the steel frame that receives the leaf and fixes into the wall. The frame is wider and taller than the leaf because it includes rebates, stops, and fixing surfaces.

A common mistake is ordering a “1000 x 2100 mm door” when the site actually needs a 1000 x 2100 mm clear opening. Those are different requirements.

Single-Leaf Fire Door Sizes

A single-leaf fire door has one movable panel and is the most common configuration for standard rooms and corridors.

KORINDIA’s standard single-leaf fire rated door size is 1000 x 2100 mm. This size suits many commercial and industrial applications where one-person passage, routine access, or service-room entry is required.

Typical single-leaf applications include:

  • Electrical and panel rooms
  • Staircase enclosures
  • Corridor doors
  • Storage and utility rooms
  • Plant rooms
  • Office fire compartments
  • Hospital service areas

For projects needing a wider single panel, the door design must be checked by the manufacturer. A wider leaf changes the load on hinges, the closing behaviour, the frame reinforcement, and the tested door assembly. KORINDIA’s guidance notes that single-leaf doors can serve standard applications up to approximately 1250 mm wide, but larger sizes require engineering confirmation.

Double-Leaf and Unequal-Leaf Fire Doors

A double-leaf fire door has two panels, usually meeting at the centre. It is used where a single leaf is too narrow for safe movement, equipment handling, or emergency evacuation.

KORINDIA’s standard double-leaf fire rated door size is 2000 x 2100 mm, meaning two 1000 mm wide leaves with a 2100 mm height. This configuration is commonly used for FD 60 applications and can be engineered for higher ratings where the tested design permits.

Equal double leaf

In an equal double-leaf door, both panels are the same width. For a 2000 x 2100 mm door, each leaf is typically 1000 mm wide.

This layout works well for:

  • Fire exits
  • Warehouse access points
  • Utility corridors
  • Industrial plant rooms
  • Large service areas

Unequal double leaf

An unequal-leaf door has one wider active leaf and one narrower leaf. For example, a 1500 mm wide opening may use a 900 mm active leaf and a 600 mm leaf.

This is useful where daily traffic needs a wide passage, but the second leaf is required only for emergency egress or equipment movement. The narrower leaf can remain closed normally and open when needed.

Unequal-leaf sizes are generally project-specific because the leaf split, hinges, panic hardware, coordinator, and closing sequence must be engineered correctly.

Why Door Size Affects Certification

A fire door is not certified as a standalone panel. Its rating applies to the complete tested assembly: leaf, frame, seals, hinges, closer, lock or panic device, vision panel if provided, wall condition, and installation method.

This is why a door larger than the tested specimen may not automatically be covered by the same certificate.

If a manufacturer tests a 1000 x 2100 mm FD 60 door, that result does not automatically prove that a 1400 x 2400 mm version will perform for 60 minutes. A larger leaf may distort differently under heat, place greater stress on the frame, and require different reinforcement or hardware.

Therefore, before ordering a non-standard size, ask the manufacturer to confirm whether the requested dimensions fall within the tested size range or require a separate assessment. KORINDIA offers customer-specific sizes, but each size should be checked against the applicable fire-rating design before production.

In short: a bigger door is not simply a scaled-up version of a smaller certified door.

How to Measure an Opening Before Ordering

Civil Engineer Measuring Structural Wall Opening Width And Thickness For Fire Door Installation On An Indian Construction Site

Accurate measurement prevents costly changes after the wall is built. Use the following steps before requesting a quotation.

  1. Confirm the door location and wall type. Note whether the wall is RCC, brick, blockwork, drywall, or a partition system. The fixing method and frame detail depend on the wall construction.
  2. Measure the structural opening width. Measure at the top, middle, and bottom of the opening. Use the smallest measurement as the controlling width.
  3. Measure the structural opening height. Measure at the left, centre, and right. Use the smallest measurement as the controlling height.
  4. Check wall thickness. Record the finished wall thickness at several points. This helps the manufacturer recommend a suitable frame profile and fixing arrangement.
  5. Decide the required clear opening. Confirm the minimum clear width and height needed for people, trolleys, stretchers, pallets, or equipment.
  6. Identify the door configuration. Decide whether a single leaf, equal double leaf, or unequal double leaf is required.
  7. Mark the swing direction. Note whether the door opens inward or outward, and whether it should be left-hand or right-hand opening. Fire doors must not obstruct escape routes.
  8. List the hardware and finish. Include the closer, panic bar, lock, vision panel, ventilation louvre, kick plate, and powder-coating colour if required.
  9. Send a dimensioned drawing. Share a plan and elevation drawing showing the opening size, wall thickness, floor level, swing direction, and required fire rating.
  10. Request a size check before civil completion. Ask KORINDIA to confirm the recommended structural opening, leaf size, and frame size before the wall opening is finalised.

Opening Size, Leaf Size and Frame Size

The table below shows an indicative relationship between opening size, leaf size, and frame size. Final dimensions depend on the selected frame profile, wall type, hardware, and tested door design.

Required door configurationIndicative leaf sizeIndicative structural opening sizeNotes
Single leaf1000 x 2100 mmApprox. 1100 x 2200 mmStandard KORINDIA single-leaf size
Single leaf, widerUp to approx. 1250 mm wideProject-specificRequires engineering and certification check
Equal double leaf2 x 1000 x 2100 mmApprox. 2100 x 2200 mmStandard KORINDIA double-leaf size
Unequal double leafExample: 900 + 600 x 2100 mmProject-specificLeaf split depends on access and egress needs
Custom fire doorAs per drawingAs per drawingRequires drawing-based engineering review

The structural opening sizes above are indicative only. Do not use them as final construction dimensions without written confirmation from the door manufacturer.

Custom Fire Door Sizes

Custom Unequal Double Leaf Steel Fire Rated Door Installed In A Modern Hospital Corridor For Wide Passage

Not every project fits a catalogue size. Industrial facilities, hospitals, data centres, warehouses, and manufacturing plants often need wider openings for machinery, beds, trolleys, pallets, or forklifts.

KORINDIA provides custom fire door sizes after reviewing the drawing, wall condition, required rating, hardware, and installation method. The company manufactures fire rated doors in FD 60, FD 90, and FD 120 ratings, making custom sizing possible across different levels of fire protection.

A custom fire door size may be required when:

  • The opening is wider than 2000 mm
  • The height exceeds 2100 mm
  • Equipment or beds need a wider clear passage
  • The wall opening is already constructed
  • An unequal leaf split is needed
  • A special frame profile or wall detail is involved
  • The door must coordinate with a specific architectural finish

Before approving a custom size, KORINDIA’s team checks whether the requested dimensions can be manufactured within the relevant tested design. If the size falls outside the approved range, the company advises an alternative configuration or a revised opening size.

Can a Fire Door Be Trimmed on Site?

Usually, no. Trimming a fire rated door on site can change the leaf construction, edge sealing, core continuity, and gap tolerances. These changes may affect the door’s ability to resist fire and smoke.

A fire door should be manufactured to the required size, not cut down after delivery. If a size adjustment is unavoidable, consult the manufacturer’s engineering team first. They can confirm whether trimming is permissible for that specific door design and, if so, what maximum allowance applies.

The safest approach is simple: measure correctly, confirm the opening before civil work, and order the door to size.

Standard Fire Door Height and Width in India

There is no single mandatory “standard” fire door height and width for every building in India. Requirements depend on the building use, occupancy, escape strategy, and the fire-safety design.

However, 2100 mm is a common door height, and 1000 mm is a common single-leaf width. KORINDIA’s standard sizes follow this practical approach: 1000 x 2100 mm for single leaf and 2000 x 2100 mm for double leaf.

For larger openings, a double-leaf arrangement is usually more practical than attempting an oversized single leaf. It distributes the weight across two panels, improves handling, and supports easier emergency escape.

How to Send a Drawing for a Size Check

To get an accurate size recommendation from KORINDIA, send the following details:

  • Architectural plan and door elevation
  • Structural opening width and height
  • Required clear opening
  • Wall type and thickness
  • Fire rating required: FD 60, FD 90, or FD 120
  • Single-leaf or double-leaf preference
  • Swing direction and handing
  • Hardware requirements
  • Vision panel or louvre requirement
  • Site photographs, if the opening already exists

KORINDIA’s team can then confirm whether a standard size works or whether a custom fire door size is required. This check is especially valuable before the wall opening is cast or masonry work is completed.

FAQs

What is the standard fire door height in India?

A common standard fire door height is 2100 mm. KORINDIA’s standard single-leaf and double-leaf fire rated doors use a 2100 mm height, with widths of 1000 mm and 2000 mm respectively.

What is the standard single-leaf fire door size?

KORINDIA’s standard single-leaf fire rated door size is 1000 x 2100 mm. This is suitable for many corridor, staircase, electrical-room, and service-room applications.

What is the standard double-leaf fire door size?

KORINDIA’s standard double-leaf fire rated door size is 2000 x 2100 mm, typically made from two 1000 mm wide leaves.

Can a fire door be trimmed on site?

Generally, no. Site trimming can affect the tested door construction, seals, gaps, and fire performance. Always confirm with the manufacturer’s engineering team before cutting or altering a fire rated door.

Can I order a custom fire door size?

Yes. KORINDIA offers customer-specific fire door sizes after reviewing the drawing, wall type, required fire rating, hardware, and installation conditions.

What is the difference between leaf size and opening size?

Leaf size is the size of the door panel. Opening size is the gap in the wall. The structural opening must be larger than the leaf to accommodate the frame and installation clearance.

Final Guidance

Fire rated door sizes should be fixed early in the project, not after the wall is built. Start with the required clear passage, add the frame and installation allowances, and then confirm the leaf and frame dimensions with the manufacturer.

For standard applications, KORINDIA’s 1000 x 2100 mm single leaf and 2000 x 2100 mm double leaf sizes cover a wide range of Indian commercial and industrial requirements. For non-standard openings, share the drawing early so the team can recommend a compliant, buildable, and certified solution.

Related Articles